24 Volt / 27.1 amp Industrial Battery Charger


ATTN: Delta Q ic650 chargers do not come with A/C or D/C harness, although we can provide them at an additional cost.

The Delta-Q IC650 Charger uses an innovative sealed die cast aluminum enclosure to provide the ultimate in reliability. Featuring a patented USB host port, the IC650 can easily download months of charge tracking data to a USB flash drive, which can also be programmed to update the charger software and QuiQ™ charging profiles. The IC650 is sold in 24, 36 and 48 volts of direct current (VDC) models.


Delta-Q has announced the introduction of the first sealed, IEC-compliant ac power cord. This new product provides sealing to an IP66 rating for the IEC60320 (formerly IEC320) C14 ac input connectors on Delta-Q IC650, QuiQ or QuiQ-dci industrial battery chargers. By preventing dirt, dust, water and other contaminants from entering the ac input fixture, charging safety and system durability are both increased. The sealed connection will prevent damage from fluids, dirt or acid corrosion, as well as maintaining a firm connection between the power cord and inlet.


Features

Benefits

Rugged, sealed aluminium die cast enclosure

Protected against high vibration, extreme temperatures and water, chemical and dust ingress Installable on- or off-board in any orientation

Two-way communication through charger USB host port

USB flash drive retrieves detailed charging logs and updates charger software and QuiQ charge profiles Saves technician field visits by providing info for battery maintenance or troubleshooting

Wide AC input voltage range, high efficiency and unity power factor

Operates on any single-phase grid worldwide Meets CEC energy efficiency standards
Reduced electricity costs

QuiQTM optimized charging profiles for all popular industrial battery brands and types

Extend battery life and minimize charge times
Auto- recharge for low voltage / storage ensures equipment is ready for use

CAN bus and Modbus communication

Integrate charger with battery management system and vehicle / machine electronicsDelta

Features

  • ✜  Multi-colour LED indicator for AC source, battery status (<80% / >80% / completion), charging, alarm, fault

  • ✜  Numeric display for charge profile, alarm / fault codes

  • ✜  Field programmable with up to 25 QuiQTM charge profiles

  • ✜  OEM customizable, field replaceable cable design


  • Unique sealed die cast enclosure (IP66 rating) for protection vs. water, dirt, chemicals, vibration, shock and temperature changes

  • Two-way communication through USB host port; download charge cycle data or update charger software with a USB flash drive

  • Global AC input, high power conversion efficiency (93.5%) and compliant with California Energy Commission (CEC) energy efficiency standards

  • QuiQ™ charging profiles for lead acid (wet, AGM, GEL) and lithium ion batteries

  • Designed for on- and off-board applications; optional CAN bus on-board communication functionality







Features

The Delta Q IC650 Charger provides 650 watts of DC output power and is available in three output voltages —24V, 36V and 48V for usage in applications such as lift trucks, floor cleaning machines, aerial work platforms, and electric scooters.

• The IC650 is built within a fully sealed die cast aluminum enclosure to withstand the high vibration and exposure to dust and moisture that is typical of on-board environments.
• Ability to use a USB memory stick to download the charger’s data log or update its software.

Rugged, Sealed Aluminium Die Cast Enclosure
• Protected against high vibration, extreme temperatures and water, chemical and dust ingress
• Installable on- or off-board in any orientation

Two-way communication through charger USB host port 
• USB flash drive retrieves detailed charging logs and updates charger software and QuiQ charge profiles
• Saves technician field visits by providing info for battery maintenance or troubleshooting

Wide AC input voltage range, high efficiency and unity power factor
• Operates on any single-phase grid worldwide
• Meets CEC energy efficiency standards
• Reduced electricity costs

QuiQ™ optimized charging profiles for all popular industrial battery brands and types
• Extend battery life and minimize charge times
• Auto- recharge for low voltage / storage ensures equipment is ready for use

CAN bus and Modbus communication
• Integrate charger with battery management system and vehicle / machine electronicsDelta


DC Output24 VDC36 VDC48 VDC
Normal DC Output Voltage24 V36 V48 V
Maximum DC Output Voltage36 V54 V72 V
Maximum DC Output Current27.1 A18.1 A13.5 A
Maximum DC Output Power650 W650 W650 W
Deep Discharge Recovery -Minimum voltage1.2 V1.8 V2.4 V
Maximum Interlock Current1 A1 A1 A
Battery TypeLead acid (Wet / AGM / GEL), lithium ion
Reverse PolarityElectronic Protection with Auto-Reset
Short CircuitElectronic Current Limit
Mechanical
Dimensions25.2 x 18.6 x 8 cm (9.9 x 7.3 x 3.1”)
Weight< 3 kg (< 6.5 lbs)
AC input connectorIEC320 / C14 (requires country-specific cord)
DC output connectorM6 threaded fasteners for ring terminals
Service portSealed (IP66) USB 2.0 Host Port (Type A) with dust cover
Mounting holesAllows for safe installation on shelf, wall or bulkhead
CoolingNormal operation in any orientation with passive cooling only
Regulatory
Efficiency93.5% peak, California Energy Commission compliant
SafetyUL1564, CSA 107.2, EN 60335-2-29
EmissionsFCC Part 15 / ICES 003 Class A, EN55011
ImmunityEN61000-3-2, EN61000-3-3, EN 61000-4-2/-3/-4/-5/-6/-11
Environmental
EnclosureIP66 (NEMA4)
Operating Temperature-40°C to +65°C (-40°F to 149°F) Derated at >40°C (104°F)
Storage Temperature-40°C to +85°C (-40°F to 185°F)
AC Input
AC Input Voltage Range85-270 VAC
Normal AC Input Voltage100-240 VAC
Normal AC Input Frequency50 / 60 Hz
Maximum AC Input Current7.5 A
Nominal AC Input Current7.3 A @ 100 VAC
3.1 A @ 230 VAC
6 A @ 120 VAC
2.9 A @ 240 VAC
Nominal AC Power Factor>0.99 @ 120 VAC>0.98 @ 230 VAC

Golf Car Chargers for Sale

Australian Grand Prix (2011) RESULT

Sun, 27 Mar 2011

The 2011 F1 Season starts in Melbourne Update: The Saubers – which finished a creditable seventh and eighth – have been disqualified for a technical infringement with their rear wing. Which moves the two Force Indias in to ninth and tenth places. It should all have happened a couple of weeks ago, of course.

Jaguar executive O'Driscoll to retire in March

Mon, 11 Oct 2010

Mike O'Driscoll, the managing director at Jaguar Cars, has announced his plan to retire at the end of March 2011. O'Driscoll, 54, moved to the United Kingdom to lead the company's brand after Ford announced its plan to sell Jaguar and Land Rover. While there, he managed the introduction of the XF, the XK, and the XJ.

Jaguar puts C-X75 supercar on ice

Tue, 11 Dec 2012

Jaguar has reversed its plan to sell the C-X75 hybrid supercar, fearing the project could be a commercial failure unable to recoup its investment. ‘After a thorough reassessment of the market conditions, the company’s view is that the global economic landscape does not currently support the introduction of a supercar such as C-X75,’ said Adrian Hallmark, Jaguar global brand director. Together with project partner Williams F1, Jaguar has built five prototypes of the plug-in hybrid.